Flow meters screw PPV for the oil product account and other liquids, It is used in the marine industry
The principle of action of screw counters of a liquid reminds work and consists in that two screws taking place in gearing rotate under action of a stream of a liquid, measure at each revolution some volume. Rotation of screws through magnetic coupling, is transferred in the accounting mechanism, being transformed to units of volume.
Characteristics
Type of the counter | The account device scale factor, l | Nominal bore,DU, mm | Working pressure, МPа | Temperature of measured liquid, °С | Class of accuracy | Weight, kg | |
mechanical | electronic | ||||||
PPV-100/1,6 | 10 | 1 | 100 | 1,6 | from -50 up to +50 | 0,25; 0,5 | 45 |
PPV-100/6,4 | 10 | 1 | 100 | 6,4 | from -50 up to +50 | 0,25; 0,5 | 135 |
PPV-150/1,6 | 10 | 1 | 150 | 1,6 | from -50 up to +50 | 0,25; 0,5 | 270 |
PPV-150/6,4 | 10 | 1 | 150 | 6,4 | from -50 up to +50 | 0,25; 0,5 | 270 |
At the order of flow meters it is necessary to specify viscosity of a measured liquid in SSt or its name (gasoline, kerosene, diesel, oil, MDO, IFO)
Type of the counter | Class of accuracy | Range of viscosity of measured liquid, SSt | ||||||||
0,55-1,1 | 1,1-6,0 | 6,0-60 | 60-300 | ||||||||
The consumption, m3/h | ||||||||||
min | nom | max | min | nom | max | min | nom | max | ||
PPV-100/1,6 | 0,25 | 18 | 120 | 180 | 18 | 120 | 180 | 18 | 120 | 180 |
0,5 | 15 | 120 | 180 | 15 | 120 | 180 | 15 | 120 | 180 | |
PPV-100/6,4 | 0,25; 0,5 | 18 | 120 | 180 | 18 | 120 | 180 | 18 | 120 | 180 |
PPV-150/1,6 | 0,25; 0,5 | 30 | 250 | 420 | 30 | 250 | 420 | 30 | 250 | 420 |